GE Micom Agile P346 Numerical relay Alstom Generator Protection relay

GE Micom Agile P346 Numerical relay Alstom Generator Protection relay

Product Details:

X

Product Description

GE Micom Agile P346 Numerical relay Alstom Generator Protection relay

Micom Alstom P346 numerical relay also known as GE Micom Agile P346 numerical relay or the Micom P346 Generator Protection System provides flexible and reliable integration of protection, control, monitoring and measurement functions for a wide range of applications. The GE P346 Relay platform, Alstom P346 Relays is available in seven models that cover most installations from small generators to sophisticated systems including generator-transformer applications and large variable speed double fed induction pumped storage machines.

GE Micom Agile P346 Key features:

  • Comprehensive, flexible communications options with a number of protocols and ports available
  • User-friendly programmable scheme logic allows easy customization of the protection and control functions
  • Binary inputs offer programmable pickup voltage thresholds and filtering enabling a truly universal application
  • High break output contacts eliminate reliance on auxiliary devices
  • Unique low frequency protection for variable speed double fed induction machines
  • Rotor earth fault protection
  • GE's Agile P346 generator protection solutions provide extensive functionality to meet all generator and generator – transformer applications, including differential protection for fast and selective tripping of phase and earth faults. All generator protection, control, monitoring, recording and communications components are housed within one box, and the solutions are accompanied by a comprehensive library of hardware options, protection and control functions to meet system requirements.

GE Micom Agile P346 Key benefits:

  • Extensive condition based monitoring features for generators and transformers
  • Graphical programmable scheme logic eases protection scheme creation and avoids the need for external logic controllers
  • Range of different protocols (MODBUS, DNP3, IEC 60870-5-103 and IEC 61850) are available
  • IEC 61850 / DNP3.0 redundant Ethernet, supporting self healing ring, RSTP, dual homing or PRP

Alstom P346 Numerical Relays Main characteristics:

  • Sensitive rotor earth fault protection using low frequency injection method
  • Harsh Environment Option to protect against corrosive gases such as H2S or SO2
  • Generator and transformer thermal overload, transformer loss of life and through fault monitoring
  • Extensive protection for large machines such as pole slipping and 100% stator earth fault protection (3rd harmonic and low frequency injection method)
  • We offer Micom Alstom P346 relay and GE’s century long tradition of power system innovation. From generators to transmission lines, to motors and beyond, we ensure dependable, safe power worldwide. GE offers a wide range of single function and auxiliary relays, along with a portfolio of accessories, to support high performing and reliable protection and control systems. Explore GE numerical Relays portfolio with us!